Spiegato, Home

Manufacturing and Industry · Electricity

What Are Electrical Insulators? Materials, Uses and Limits

  • Published by Spiegato
  • Updated
  • 10 min read

The short answer

Electrical insulators are materials whose electrons stay bound to their atoms, so current barely flows through them [1]. Glass, porcelain, rubber and most plastics are common examples: they coat wires, plugs and appliances and hold up high-voltage lines. No insulator is perfect, though. Push enough voltage across it, or let it get damaged, and it can fail.

What is an electrical insulator, in plain terms?

An electrical insulator is a material that doesn't let current through, or lets so little through that you can ignore it. The reason comes down to electrons. In metals, some electrons are free to roam; in insulators, electrons and ions are bound in the material's structure and move as much as 1023 times more slowly than in a conductor [1]. Glass, rubber, many plastics, pure water and dry table salt are insulators, while metals and salty water are conductors [1].

In everyday life, insulators do two jobs. The first is keeping current where it belongs: the plastic jacket around the copper in a lamp cord makes sure electricity flows through the metal and not through your hand. The second is holding things apart: the strings of discs and the ribbed posts you see on utility poles and transmission towers support high-voltage lines and keep them isolated from the grounded structure [5]. You'll also see these materials called "dielectrics." It's the same kind of material, described by how it reacts to an electric field.

Why do some materials insulate and others conduct?

The property that separates them is resistivity: the higher it is, the harder the material fights the flow of current. The gap between a good conductor and a good insulator isn't a factor of a few. It's billions of billions. Here are some values measured at 68 °F (20 °C):

Resistivity at 68 °F (20 °C) of some conductors and insulators
MaterialTypeResistivity (Ω·m)
SilverConductor1.59 × 10-8
CopperConductor1.68 × 10-8
AluminumConductor2.65 × 10-8
WoodWeak insulator108 to 1011
GlassInsulator109 to 1014
MicaInsulator1011 to 1015
Teflon (PTFE)Insulatormore than 1013
Hard rubberInsulator1013 to 1016
Fused quartzInsulator7.5 × 1017

These come from a university reference table [2], and for many insulators the value is a wide range rather than one number. Let's run the numbers for glass: 109 divided by 1.68 × 10-8 is about 6 × 1016, and 1014 divided by the same figure is about 6 × 1021. In other words, a piece of glass with the same shape and size as a piece of copper resists current tens of quadrillions of times more strongly, at the very least. If you're wondering why copper ended up as the standard wire metal, see whether copper is the best electrical conductor.

What materials are used as electrical insulators?

No insulator is right for every job. Engineers pick based on voltage, temperature, environment (rain, sun, dirt, chemicals) and weight. This table sums up the most common choices:

Common insulating materials: where they're used and what they're good at
MaterialWhere you'll find itStrengthsDrawbacks
Porcelain and glassInsulators on overhead high-voltage linesDecades of service experience, excellent resistance to electrical and environmental stress, cost effective [5]Bulky, labor-intensive to install and maintain, poor performance in heavily polluted areas [5]
Silicone rubberComposite (polymer) insulators for power linesLight, surface stays water-repellent even in rain, excellent breakdown strength [5]Mechanically weak, expensive, ages under sun, UV and moisture [5]
EPDM and epoxy resinsOutdoor composite insulatorsEPDM resists surface tracking and erosion better and is mechanically stronger [5]Early outdoor epoxy insulators suffered surface damage and performed poorly in the cold [5]
PTFE (Teflon) and high-density polyethyleneLow-voltage uses, indoors and outdoors [5]Very high resistivity [2]Used mainly at low voltage [5]
Polyimide film (such as Kapton)Thin insulation in equipment and electronicsUsed from -452 °F (-269 °C) up to 752 °F (400 °C), withstands high voltage at a thickness of about one thousandth of an inch [4]An engineering material, not something for home DIY
RubberInsulating gloves, blankets and sleeves for electrical workersMade in classes rated for use from 500 to 36,000 V [6]Damaged by ozone, light, heat, humidity and cuts [6]

A bit of history: polymer insulators for power lines arrived around 1960, and the first outdoor ones, made of epoxy resin, went into service in the UK in the early 1960s [5]. In a modern composite insulator, the outer sheds (the "fins") are polymer, usually silicone rubber or EPDM, while a fiberglass rod inside carries the mechanical load [5]. To go further, there's an overview of the different types of electrical insulators, a piece on polymer insulators and one on the classic pin insulator found on utility poles.

Can an insulator stop insulating?

Yes, and that's the most important thing to know. Insulators work within limits, and there are three main ways they give out.

  • Too much voltage. Every insulator has a threshold at which the electric field rips electrons off its molecules and the material suddenly conducts. This is called dielectric breakdown [3]. For dry air, the threshold is about 3 kV per millimeter [3].
  • Water and dirt. Pure water insulates, but salty water conducts [1]. Contaminants and water droplets on an insulator's surface can form a conducting path for leakage current, which on outdoor insulators can cause surface discharges and erosion [5].
  • Aging and damage. Organic materials such as rubbers and resins age with heat, sunlight, UV and moisture [5]. For insulating gloves, OSHA lists defects that bar them from use: holes, tears, punctures, cuts, ozone cracking, embedded foreign objects, and texture changes such as swelling, softening, hardening or stickiness [6].

That's why a cord with cracked insulation isn't "mostly safe." The copper underneath is still live, and whatever protection is left may not be enough.

How do you check cords and extension cords at home?

You don't need a meter for a first check: a careful look with the cord unplugged does most of the work. OSHA requires workers to inspect portable cord-and-plug equipment and extension cords this way before each shift, and the same routine makes sense at home [7].

  1. Unplug the cord from the outlet before handling it for inspection.
  2. Run your eyes along the whole outer jacket, looking for cuts, cracks and spots where you can see the colored inner wires.
  3. Look for signs of internal damage, such as pinched or crushed sections where the cord runs under a door or furniture [7].
  4. Check the plug: loose parts and bent or missing prongs are warning signs [7].
  5. If you find damage, stop using the item until it has been repaired and tested [7]. For an appliance or your home's fixed wiring, call a licensed electrician.

One thing worth knowing: some portable tools and appliances are built with double insulation. Under OSHA rules, listed or labeled portable tools and appliances protected by an approved double-insulation system, and distinctively marked as such, don't need to be grounded [8]. That's why a double-insulated tool can come with a two-prong plug. To learn more about what happens inside the wall, read how an electrical outlet works; for what current does to the body, see the article on electrocution.

On the job, the starting rule in the US is clear: live parts that workers may be exposed to must be de-energized before anyone works on or near them, unless the employer can show that shutting them off creates greater hazards or isn't feasible [9]. Insulating gloves are a tool for trained, qualified people, not permission to work on a live circuit. If someone has been shocked and is hurt, call 911.

For the curious: how much voltage can an insulator take?

The threshold we mentioned is called dielectric strength, usually given in kilovolts per millimeter (kV/mm): how much voltage each millimeter of material withstands before it breaks down. Some reference values:

Dielectric strength of some insulators and breakdown voltage for a given thickness
Material and thicknessDielectric strengthBreakdown voltage (calculated)
Dry air, 1 mm (0.04 in)3 kV/mm [3]3 × 1 = 3 kV
Teflon, 1 mm (0.04 in)60 to 173 kV/mm [3]at least 60 × 1 = 60 kV
Mica, 1 mm (0.04 in)118 kV/mm [3]118 × 1 = 118 kV
Kapton HN film, 1 mil (0.0254 mm)303 kV/mm [4]303 × 0.0254 ≈ 7.7 kV
Kapton HN film, 2 mil (0.0508 mm)240 kV/mm [4]240 × 0.0508 ≈ 12.2 kV
Kapton HN film, 5 mil (0.127 mm)154 kV/mm [4]154 × 0.127 ≈ 19.6 kV

Look at the last column: a film five times thicker doesn't withstand five times the voltage, only about two and a half times as much (19.6 divided by 7.7 is about 2.5). That's because the strength per millimeter drops as the film gets thicker [4]. For more, there's a dedicated article on dielectric strength.

Keep in mind these are lab values, measured with a specific test method (ASTM D149 for Kapton) [4], not working voltages. Real designs leave a wide margin. Rubber insulating gloves are a good example: Class 00 gloves are rated for a maximum use voltage of 500 V but are retested at 2,500 V AC [6].

Rubber insulating gloves and equipment: classes and voltages under OSHA
ClassMaximum use voltage (V, AC rms)Retest voltage (V, AC rms)
005002,500
01,0005,000
17,50010,000
217,00020,000
326,50030,000
436,00040,000

Source for the table: OSHA's electrical protective equipment standard [6], which also requires gloves to be electrically tested before first issue and every 6 months, and blankets and sleeves every 12 months.

Frequently asked questions

What is the best electrical insulator?

There's no single winner, because the right choice depends on voltage, temperature and surroundings. Among the materials in a standard physics reference table, fused quartz has the highest resistivity, about 7.5 × 10^17 Ω·m [2]. For outdoor power lines, rain and dirt matter too: porcelain and glass have decades of service behind them but struggle in heavily polluted areas, while silicone rubber stays water-repellent even when wet [5].

Is wood an electrical insulator?

Wood is classed as an insulator, but a weak one: its resistivity runs from about 10^8 to 10^11 Ω·m, compared with up to 10^14 Ω·m for glass and up to 10^16 Ω·m for hard rubber [2]. That's why a wooden tool or ladder shouldn't be treated as reliable protection against shock.

Is water a conductor or an insulator?

Pure water is an insulator, but salty water conducts [1]. On a wet or dirty insulator, contaminants and water droplets can form a path for leakage current across the surface, and on outdoor insulators that can lead to discharges and erosion [5]. Keep electricity and water apart.

What's the difference between an insulator and a dielectric?

They're the same kind of material seen from two angles. You call it an insulator when what matters is that current doesn't flow, and a dielectric when what matters is how it responds to an electric field, for example inside a capacitor, where Teflon has a dielectric constant of about 2.1 [3].

How often do electricians' rubber gloves have to be tested?

Under OSHA rules, insulating gloves must be inspected and given an air test before each day's use, and electrically tested before first issue and every 6 months after that [6]. Rubber insulating sleeves and blankets are retested every 12 months [6]. Gloves with holes, cuts, ozone cracks or texture changes such as swelling or stickiness may not be used [6].

Sources

  1. College Physics 2e, 18.2 Conductors and Insulators. OpenStax, Rice University
  2. University Physics Volume 2, 9.3 Resistivity and Resistance (Table 9.1). OpenStax, Rice University
  3. University Physics Volume 2, 8.5 Molecular Model of a Dielectric (Table 8.1). OpenStax, Rice University
  4. Kapton HN polyimide film: product properties. Qnity Electronics (formerly DuPont Electronics)
  5. Review of the Performance of High-Voltage Composite Insulators (Saleem M. Z., Akbar M., Polymers, 2022). Polymers (MDPI), via PubMed Central
  6. 29 CFR 1910.137, Electrical Protective Equipment. U.S. Occupational Safety and Health Administration (OSHA)
  7. 29 CFR 1910.334, Use of equipment. U.S. Occupational Safety and Health Administration (OSHA)
  8. 29 CFR 1910.304, Wiring design and protection. U.S. Occupational Safety and Health Administration (OSHA)
  9. 29 CFR 1910.333, Selection and use of work practices. U.S. Occupational Safety and Health Administration (OSHA)

Topics

Related articles

  • What Are the Different Types of Electrical Insulators?

    An electrical insulator is a material that does not conduct electricity. Such materials can include ceramic, glass, non-ceramic, rubber and silicon…

  • What Limits Electricity Transmission?

    There are several key factors that limit electricity transmission, such as the distance between the generator and the end user, the power of the original…

  • What Is a Pin Insulator?

    A pin insulator is a device that is designed to support some type of wire, such as telephone wire, from direct contact with whatever structure is used in…

  • What Is Electrical Bonding?

    Electrical bonding is an electrical safety measure intended to prevent accidental electrical shock. Buildings, whether residential, commercial, or…

  • What is an Electrical Generator?

    An electrical generator is a device that generates electricity from mechanical energy, usually via electromagnetic induction. Electromagnetic induction…