The short answer

Electrical resistivity measures how strongly a material opposes electric current, regardless of the object's size or shape. It's expressed in ohm-meters (Ω·m). The lower it is, the better the material conducts: standard copper wire is about 1.72 × 10⁻⁸ Ω·m at 68 °F (20 °C) [1], while insulators are many orders of magnitude higher.

What is electrical resistivity, in plain terms?

Picture two wires that are exactly the same length and thickness, one made of copper and one made of iron. Run current through them and the iron wire pushes back much harder. That difference has nothing to do with the wire's shape. It comes from the material itself, and it's called electrical resistivity: a kind of electrical fingerprint for every substance.

The UK's National Physical Laboratory puts it in very concrete terms: resistivity is the resistance you'd measure between opposite faces of a cube of the material one meter on each side [2]. That's why the unit is the ohm-meter (Ω·m). The smaller the number, the more easily current flows; the bigger it is, the more the material acts like an insulator.

Resistivity isn't a fixed universal constant, though. It changes with temperature, and it usually goes up with impurities, porosity and cold working of the metal [2]. That's why reference tables always state a temperature and use samples that are as pure as possible.

What's the difference between resistance and resistivity?

This is the question most people actually have, and the two are easy to mix up. Resistance (R) belongs to a specific object: this cord, that resistor, the coil in your space heater. It's measured in ohms, and under the International System of Units one ohm is one volt divided by one ampere [3]. It's the quantity in Ohm's law: put 1 volt across a 1-ohm object and 1 ampere of electric current flows.

Resistivity (ρ, the Greek letter "rho") belongs to the material. The two are tied together by a simple formula:

R = ρ × L / A

where L is the conductor's length and A is its cross-sectional area. In practice:

  • double the length of a wire and its resistance doubles;
  • double the cross-sectional area and the resistance is cut in half;
  • switch materials and ρ changes, so everything else does too.

The flip side of resistivity is electrical conductivity (σ = 1/ρ), measured in siemens per meter. The siemens is simply the reciprocal of the ohm, one ampere per volt [3]. They're two ways of describing the same property: one looks at the obstacle, the other at how easily current gets through.

Which materials conduct best and worst?

The spread between materials is far bigger than most people expect. Here are values at 32 °F (0 °C) from the National Physical Laboratory tables. The third column converts them to microhm-centimeters (µΩ·cm), a unit you'll often see in materials data, where 1 µΩ·cm equals 10⁻⁸ Ω·m.

Resistivity of common materials at 32 °F (0 °C) [2]
MaterialResistivity (× 10⁻⁸ Ω·m)In µΩ·cmWhat it's like
Silver1.471.47Best conductor among common metals
Copper1.541.54The standard metal for electrical wire
Gold2.052.05Excellent conductor
Aluminum2.422.42About 1.6 times copper's resistivity
Tungsten4.824.82Resistivity climbs steeply as it heats up
Iron8.578.57Mediocre conductor
Stainless steel55.055.0An alloy that conducts far worse than pure iron
Nichrome (nickel-chromium)107.3107.3High-resistivity alloy

What about semiconductors? At normal temperature, silicon sits somewhere between about 0.1 and 60 Ω·m depending on its impurities [2]. Even at the low end, that's millions of times higher than copper. That sensitivity to deliberately added impurities is exactly what makes silicon so useful in electronics. Insulators sit higher still; for that end of the scale, see what electrical insulators are.

One fun fact about the top of the chart: copper isn't the very best conductor. Silver beats it by roughly 5%. There's more on that in is copper the best electrical conductor?

How do you calculate the resistance of a wire?

This is where resistivity gets practical. Say you want to run power to a tool at the far end of your yard, 50 feet from the outlet, with copper wire. Current has to go out and come back, so you have 100 feet of conductor in total.

US wire tables use a handy version of resistivity: standard annealed copper is 10.371 ohm-circular mils per foot at 68 °F (20 °C) [1]. A circular mil is the area of a circle one thousandth of an inch across, and wire sizes are listed in those units.

  1. Look up the wire's area. A 14 AWG copper wire has a cross section of 4,110 circular mils [1].
  2. Apply R = ρ × L / A: 10.371 × 100 / 4,110 = 0.252 Ω. The published table gives 2.52 Ω per 1,000 feet for 14 AWG, the same answer [1].
  3. To find the voltage you lose along the wire, multiply by the current (Ohm's law): at 12 A, 0.252 × 12 = 3.0 V, about 2.5% of a 120-volt supply.
  4. For the power wasted as heat, use R × I²: 0.252 × 12 × 12 = 36 W.

Run the same math for thicker wire and you can see right away why wire size matters. (Remember that with the American Wire Gage, a smaller number means a thicker wire.)

Copper run of 50 ft (100 ft of conductor) carrying 12 A, at 68 °F (20 °C); resistance per 1,000 ft from NBS tables [1]
Wire sizeOhms per 1,000 ftTotal resistanceVoltage dropShare of 120 VHeat lost
14 AWG2.520.252 Ω3.0 V2.5%36 W
12 AWG1.590.159 Ω1.9 V1.6%23 W
10 AWG0.99880.100 Ω1.2 V1.0%14 W

A useful rule of thumb from the same tables: every three gauge numbers, the resistance per foot roughly doubles or halves [1]. You can see it above, since 10 AWG has about two fifths of the resistance of 14 AWG, and 11 AWG would be close to half of 14 AWG.

These numbers are here to show the principle, not to size a circuit. Choosing wire for a home follows your local electrical code and is a job for a licensed electrician, who also accounts for things this example ignores, such as how the cable is installed and how the circuit is protected. For the next step, see what voltage drop is and how wire gauge works.

Why does resistivity change with temperature?

In metals, resistivity rises as they heat up: the atoms vibrate more and get in the way of moving electrons. For copper the effect is well documented. The international standard sets its temperature coefficient at 0.00393 per °C at 68 °F (20 °C) [1]. Put simply, every 10 °C (18 °F) of warming adds about 4% to the resistance.

Here's an example. If the 14 AWG wire from the yard run were operating at 167 °F (75 °C), 55 °C above the reference temperature, its resistance would be 0.252 × (1 + 0.00393 × 55) = 0.252 × 1.216 = about 0.306 Ω. The NBS tables agree, listing 3.07 Ω per 1,000 feet for 14 AWG at that temperature [1]. A hot conductor wastes more energy, which heats it further. That's one reason undersized wire is a bad idea.

Not every material reacts the same way:

  • Copper: rises from 1.54 to 2.22 × 10⁻⁸ Ω·m between 32 °F and 212 °F (0 and 100 °C), about 44% more [2].
  • Tungsten: rises from 4.82 to about 40.3 × 10⁻⁸ Ω·m at 1,500 K (about 2,240 °F or 1,227 °C), more than eight times higher [2]. A glowing filament resists far more than a cold one.
  • Nichrome: goes only from 107.3 to 110.3 × 10⁻⁸ Ω·m between 32 °F and 1,292 °F (0 and 700 °C), roughly 3% more [2]. An alloy that stable behaves predictably even when it runs hot.

At the opposite extreme are superconductors: some metals, cooled below a critical temperature close to absolute zero, lose their resistance entirely [2].

Why do people measure the resistivity of soil?

Resistivity isn't just about wires. Geologists and engineers measure it underground to learn what's beneath their feet without digging. As the U.S. Environmental Protection Agency explains, the usual method passes direct current between two electrodes pushed into the ground and measures the voltage difference between two other electrodes that carry no current [4].

Here's the interesting part: apart from a few exotic materials such as metallic ores, the mineral grains in soil and rock are essentially nonconductive. What mostly controls the reading is the water in the pores, how resistive that water is, and how the pores are arranged [4]. So resistivity surveys help estimate the depth to bedrock, spot buried anomalies and, in coarse granular soils, find the water table (in fine-grained soils, it may not show up at all) [4].

A few things worth knowing about this technique:

  • The depth you can investigate is always less than the electrode spacing; a maximum spacing of at least three times the depth of interest is a common planning figure [4].
  • Combining many measurements along a line produces 2D images of the subsurface, and the approach extends to 3D imaging, often called electrical resistivity tomography [4].
  • The same kind of rock can give very different values depending on the water it holds, so results are interpreted alongside drill holes and other methods [4].

For the curious: the copper standard and the units

The copper figure used above isn't arbitrary. It's the International Annealed Copper Standard (IACS), adopted by the International Electrotechnical Commission in 1913 after an investigation by the U.S. National Bureau of Standards and international discussion of the results [1]. It's defined as 1/58 = 0.017241 Ω·mm²/m at 20 °C, which equals 1.7241 microhm-centimeters or 10.371 ohm-circular mils per foot [1], and it represents fairly typical commercial copper.

That's where the "percent conductivity" on conductor spec sheets comes from: it compares a sample with the standard, both at 20 °C [1]. A few reference points:

Copper compared with the International Annealed Copper Standard (IACS) [1]
Type of copperConductivity relative to the standard
International standard (annealed copper)100%
Hard-drawn wire, value to assume when no measurement is available97.5%
Annealed wire of 99.999% purityslightly over 103%

This also explains a small mismatch between tables. The very pure copper in the National Physical Laboratory data is 1.54 × 10⁻⁸ Ω·m at 0 °C [2]; scaled to 20 °C using its own trend, that's about 1.68 × 10⁻⁸ Ω·m, a bit below the IACS value, which describes ordinary commercial copper [1].

Converting between units:

  • 1 Ω·mm²/m = 10⁻⁶ Ω·m, because 1 mm² = 10⁻⁶ m²;
  • 1 µΩ·cm = 10⁻⁸ Ω·m;
  • 10.371 Ω·cmil/ft = 1.7241 × 10⁻⁸ Ω·m, so 1 Ω·cmil/ft is about 1.66 × 10⁻⁹ Ω·m [1];
  • the conductivity of standard copper is 1 / (1.7241 × 10⁻⁸ Ω·m), or about 58 million siemens per meter [1][3].

Frequently asked questions

Which metal has the lowest electrical resistivity?

Among common metals, it's silver: about 1.47 × 10⁻⁸ Ω·m at 32 °F (0 °C), compared with 1.54 × 10⁻⁸ Ω·m for copper and 2.05 × 10⁻⁸ Ω·m for gold [2]. The gap between silver and copper is only about 5%, which is why everyday wiring uses copper rather than a precious metal.

Does aluminum wire need to be thicker than copper wire?

Yes, if you want the same resistance over the same length. Aluminum's resistivity is about 1.6 times copper's (2.42 versus 1.54 × 10⁻⁸ Ω·m at 32 °F, or 0 °C) [2], so the conductor needs roughly 1.6 times the cross-sectional area. That's why an aluminum conductor ends up thicker than a copper one doing the same job.

Why does salty water conduct electricity better than fresh water?

In water, the current is carried by dissolved salts and other inorganic chemicals, so conductivity rises as salinity rises [5]. Warmer water also conducts better than cold water [5]. Organic compounds such as oil don't conduct well, so they give water a low conductivity [5].

Can a material's resistivity drop to zero?

Yes, in superconductors. Some metals lose all resistance below a very low critical temperature: about 1.17 K for aluminum, 7.2 K for lead and 9.1 K for niobium [2], just a few degrees above absolute zero. At room temperature, the same metals behave like ordinary conductors.

What is apparent resistivity in a soil survey?

It's the value you get from a ground measurement if you pretend the earth under the electrodes is uniform all the way down [4]. Real ground has layers, so each reading is really a weighted average over a large volume, with the nearest material counting most [4]. Comparing readings at different electrode spacings shows how resistivity changes with depth.

Sources

  1. Copper Wire Tables (NBS Handbook 100). National Bureau of Standards (now NIST). International Annealed Copper Standard, temperature coefficient, American Wire Gage tables
  2. Kaye & Laby, Tables of Physical and Chemical Constants: 2.6.1 Electrical resistivities. National Physical Laboratory (NPL), archived copy. Resistivities of metals, semiconductors and alloys at several temperatures
  3. The International System of Units (SI Brochure, 9th edition). Bureau International des Poids et Mesures (BIPM)
  4. Resistivity Methods, Environmental Geophysics. U.S. Environmental Protection Agency
  5. Indicators: Conductivity. U.S. Environmental Protection Agency, National Aquatic Resource Surveys

Topics

Related articles